These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Detection of pulmonary edema in pigs: storage phosphor versus amorphous selenium-based flat-panel-detector radiography. Author: Kim TS, Im JG, Goo JM, Lee KH, Lee YJ, Kim SH, Kim S. Journal: Radiology; 2002 Jun; 223(3):695-701. PubMed ID: 12034937. Abstract: PURPOSE: To compare diagnostic accuracy of soft-copy selenium-based digital radiographic images and soft-copy computed radiographic images obtained for detection of pulmonary edema in pigs. MATERIALS AND METHODS: Oleic acid was injected intraatrially into three pigs (weight, 20-25 kg) at doses of 0.04, 0.05, and 0.06 mL/kg to induce pulmonary edema. Thirty-seven sets of computed radiographic, digital radiographic, and thin-section computed tomographic (CT) scans were obtained every 20-30 minutes in three pigs over 4-6 hours. Images were masked for identity, randomly sorted, and displayed on a monitor. Four radiologists rated each image for presence of parenchymal opacities by using a dichotomous scoring system in two sessions. Presence of pulmonary edema was determined with thin-section CT and a severity scale. Intra- and interobserver variations were determined with the kappa statistic and the Z test and with the Cochran Q test and the McNemar test, respectively. True-positive, true-negative, false-positive, and false-negative rates were determined. McNemar test was used to determine statistical significance of differences in detection between computed and digital radiographic images. RESULTS: There was no significant intra- or interobserver variation, except for one pair of observers during the first interpretative session with computed radiographic images (P =.016, McNemar test). Overall sensitivity (92.1%) and diagnostic accuracy (90.2%) of digital radiography were significantly higher than those of computed radiography (79.6% and 83.4%, respectively) (P <.001 for sensitivity, P =.01 for diagnostic accuracy, McNemar test). In detection of minimal and mild pulmonary edema, sensitivity of digital radiography (84%) was significantly higher than that of computed radiography (58%) (P <.001). CONCLUSION: Soft-copy digital radiographic images are superior to soft-copy computed radiographic images obtained for detection of mild pulmonary edema in pigs.[Abstract] [Full Text] [Related] [New Search]