Search MEDLINE/PubMed
Title: Compliance with automated peritoneal dialysis. Author: Rivetti M, Battú S, Barrile P, Benotto S, Berruto L, Bosio A, d'Auria L. Journal: EDTNA ERCA J; 2002; 28(1):40-3, 55. PubMed ID: 12035903. Abstract: Compliance in peritoneal dialysis is reported as being a significant problem. In CAPD, the percentage of non-compliant patients varies between 10 and 40%. In APD the phenomenon seems to be more limited, at 15% - 20%. We considered 23 patients who had been on APD for more than 3 months.The dialytic treatment was performed using the Home Choice Pro device to record all the parameters of the dialysis session. The last 30 days of treatment were considered in the assessment of compliance, evaluating differences in daytime and night-time volumes between the prescription and the actual treatment,the length of the night-time session, and the days of treatment. As regards volume and duration, no differences were found compared to the dialytic prescriptions. For the days of treatment, a differencewas onlyfound in 3 patients: 2 self-administered patients missed day of therapy out of 30, and in both cases the missed tretment was ageed with the Centre; non-compliance was only found in 1 patient (4,3%), whose treatment was performed by the family, and who missed 4 days out of 30.[Abstract] [Full Text] [Related] [New Search]