  • Title: Cast articulation accuracy using rigid cast stabilization.
    Author: Gunderson RB, Siegel SC.
    Journal: J Prosthodont; 2002 Jun; 11(2):117-21. PubMed ID: 12087549.
    Abstract:
    PURPOSE: This study evaluated the positional accuracy of casts articulated on a semi-adjustable articulator, with and without rigid cast stabilization using either laboratory plaster or mounting plaster. MATERIALS AND METHODS: A reference articulation of melamine casts in maximum articulation was established and recorded in the horizontal and vertical dimensions using a verification device. The same casts were subsequently remounted 24 times using either laboratory plaster or mounting plaster. Half of the articulations from each group were stabilized using detachable mounting rods and sticky wax, and half were hand-articulated without stabilization, for a total of 6 articulations in each of 4 test groups. The resulting spatial positions established on the articulator were compared to the initial reference position on the verification device grid. Means and standard deviations of the absolute values of the horizontal and vertical displacement for each group were determined separately and compared using a one-way anaylsis of variance. Significant differences (p <0.05) were identified using Tukey's honestly significant difference multiple comparison test. RESULTS: Mean vertical mandibular cast displacement ranged from 0.26 +/-0.21mm for stabilized casts mounted with laboratory plaster to 1.58 +/-0.32 mm for unstabilized casts mounted with mounting plaster. For each mounting material, significantly less vertical displacement (p <0.001) was observed with the mandibular cast stabilized before mounting. The cast mounted with laboratory plaster exhibited horizontal displacement (0.87 +/-0.29 mm) that was significantly greater than the remaining groups (p <0.001), which did not differ from each other. CONCLUSIONS: Rigid stabilization of the mandibular to maxillary cast during mounting with laboratory and mounting plaster improved articulation accuracy.
    [Abstract] [Full Text] [Related] [New Search]