These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Prediction of fetal weight by ultrasound: the contribution of additional examiners. Author: Gull I, Fait G, Har-Toov J, Kupferminc MJ, Lessing JB, Jaffa AJ, Wolman I. Journal: Ultrasound Obstet Gynecol; 2002 Jul; 20(1):57-60. PubMed ID: 12100419. Abstract: OBJECTIVES: To assess the contribution of additional examiners to: the average discrepancy between estimated and actual fetal weights; the correlation between estimated and actual fetal weights; the reduction in major (> 10%) discrepancies between estimated and actual fetal weights. DESIGN: Three experienced sonographers independently measured fetal biparietal diameter, head circumference, abdominal circumference and femur length in 39 fetuses at term. The estimated fetal weights were calculated for each examiner. Fetal biometric measurements were analyzed to obtain the source of differences in estimations among the examiners. Discrepancy, correlation and number of major (> 10%) discrepancies between the estimated and actual fetal weights were calculated for each examiner, and the contribution of additional examiners was analyzed. RESULTS: The differences in measurements of the biparietal diameter and femur length were lower than those of the head and abdominal circumferences. For each of the three examiners, the average discrepancy between the estimated and actual fetal weights was 6.1%, 5.9% and 6.3%. When the estimation was based on two examiners, the discrepancy decreased to 4.8-5.6%. The contribution of a third examiner was nil. Major (> 10%) discrepancies between estimated fetal weight and actual birth weight were found in seven, eight and nine estimations of the examiners. Estimation by two examiners decreased the number of major discrepancies, and estimation by all three examiners further decreased by approximately 50% the number of major discrepancies between the estimated and actual fetal weights. CONCLUSION: Measurements by multiple examiners changes only slightly the average number of discrepancies between estimated and actual fetal weights. However, the reduction in major (> 10%) discrepancies is statistically and clinically significant.[Abstract] [Full Text] [Related] [New Search]