These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Purification of STR-multiplex-amplified microsamples can enhance signal intensity in capillary electrophoresis. Author: Lederer T, Braunschweiger G, Betz P, Seidl S. Journal: Int J Legal Med; 2002 Jun; 116(3):165-9. PubMed ID: 12111320. Abstract: In this study, the effect of sample purification on total signal intensities of samples amplified with genRES MPX-2 (nine-locus multiplex) prior to capillary electrophoretic analysis has been investigated. Sample purification with the Qiaquick PCR purification kit led to an increase of the relative fluorescent signal intensity by a factor of 3.8 +/- 0.8. In contrast, the application of larger sample volumes led to a decrease of signal intensities from 20% to 80%, depending on whether the samples were purified or not. In addition, increase of injection time showed a linear increase of signal intensity between 3 s and 10 s. Increasing the number of PCR cycles from 30 to 33 also led to a significant increase of signal intensities. Nevertheless, this increase greatly depended on the fragment lengths and was sometimes accompanied by the appearance of non-specific signals. In combination, optimisation of sample preparation and increase of injection time may intensify signals up to 12-fold, thereby increasing the overall sensitivity of the assay. This may be of special interest for forensic analysis of microspecimens containing limited amounts of DNA.[Abstract] [Full Text] [Related] [New Search]