These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An improved method for post-PCR purification for mtDNA sequence analysis.
    Author: Dugan KA, Lawrence HS, Hares DR, Fisher CL, Budowle B.
    Journal: J Forensic Sci; 2002 Jul; 47(4):811-8. PubMed ID: 12136989.
    Abstract:
    Mitochondrial DNA (mtDNA) analysis of forensic samples typically is performed when the quantity and quality of DNA are insufficient for nuclear DNA analysis or when maternal relatives may be the only reference source. Many of the steps required in the analytical process are both lengthy and labor intensive. Therefore, improvements in the process that reduce labor without compromising the quality of the data are desirable. The current procedure requires purification of the amplicons by centrifugal filtration after PCR and prior to cycle sequencing. Because this method requires several manipulations to perform, alternate cleanup procedures were investigated. These include the use of 1) Qiagen QlAquick PCR Purification columns, 2) Concert Rapid PCR Purification columns, and 3) ExoSAP-IT reagent. When the yield of purified amplicons, quality of the sequence profile, and ease of assay were evaluated, the use of ExoSAP-IT reagent for post-amplification purification was chosen to replace the filtration method.