These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus aureus (MRSA): a disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-screen latex agglutination test. Author: Felten A, Grandry B, Lagrange PH, Casin I. Journal: J Clin Microbiol; 2002 Aug; 40(8):2766-71. PubMed ID: 12149327. Abstract: Very-low-level methicillin-resistant Staphylococcus aureus (MRSA), or class 1 MRSA, is often misdiagnosed as methicillin-susceptible S. aureus (MSSA). We evaluated the performances of three methods for detection of low-level methicillin resistance: the disk diffusion method using the cephamycin antibiotics cefoxitin and moxalactam, the Vitek 2 system (bioMérieux), and the MRSA-screen test (Denka). Detection of the mecA gene by PCR was considered to be the "gold standard." We also determined the sensitivity of the oxacillin disk diffusion method with 5- and 1-microg disks and that of the Oxascreen agar assay with 6 mg of oxacillin liter(-1) for detection of MRSA. We compared the distributions of MICs of oxacillin and cefoxitin by the E-test (AB Biodisk), and those of moxalactam by dilutions in agar, for MRSA and MSSA isolates. The 152 clinical isolates of S. aureus studied were divided into 69 MSSA (mecA-negative) and 83 MRSA (mecA-positive) isolates, including 63 heterogeneous isolates and 26 class 1 isolates (low-level resistance). The cefoxitin and moxalactam disk diffusion tests detected 100% of all the MRSA classes: cefoxitin inhibition zone diameters were <27 mm, and moxalactam inhibition zone diameters were <24 mm. The Vitek 2 system and the MRSA-screen test detected 94 and 97.6% of all MRSA isolates, respectively. The sensitivities of the 5- and 1-microg oxacillin disks were 95.2 and 96.4%, respectively, whereas that of the Oxascreen agar screen assay was 94%. All of the tests except the 1-microg oxacillin disk test were 100% specific. For the class 1 MRSA isolates, the sensitivity of the Vitek 2 test was 92.3%, whereas those of the MRSA-screen test and the disk diffusion method with cefoxitin and moxalactam were 100%. Therefore, the cefoxitin and moxalactam disk diffusion methods were the best-performing tests for routine detection of all classes of MRSA.[Abstract] [Full Text] [Related] [New Search]