These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Serial determination of cardiac output during prolonged work by a CO2-rebreathing technique.
    Author: Wilson BA, Hermiston RT.
    Journal: J Hum Ergol (Tokyo); 1975 Sep; 4(1):35-41. PubMed ID: 1223209.
    Abstract:
    Cardiac outputs were calculated on eight male college students while walking on a treadmill at controlled heart rate levels. The heart rate levels were maintained through the use of a heart rate controller (Quinton Model AI-607), standard deviations for heart rate in beats/min ranged from +/-2.1 at the heart rate level 110 to +/-3.2 at 170. Test-retest correlations of the cardiac output values at the various heart rate levels were: at heart rate 110, 0.66 after 7 min and 0.85 at 30 min; at heart rate 150, 0.92 after 7 min and 0.68 at 30 min; at heart rate 130, 0.97 after 7 min, and at heart rate 170, 0.85 after 7 min. The calculated cardiac output values when plotted against oxygen uptake compare favorably with published reports. The data collected demonstrate that the CO2-rebreathing method used in the present investigation provides a reliable bloodless technique for determining multiple cardiac output during prolonged work of varied intensities.
    [Abstract] [Full Text] [Related] [New Search]