These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Creation of a dual-coronary system for anomalous origin of the left coronary artery from the pulmonary artery utilizing the trapdoor flap method. Author: Ando M, Mee RB, Duncan BW, Drummond-Webb JJ, Seshadri SG, Igor Mesia CI. Journal: Eur J Cardiothorac Surg; 2002 Oct; 22(4):576-81. PubMed ID: 12297175. Abstract: OBJECTIVE: Results of the repair of anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) have improved. Direct implantation of the anomalous coronary artery into the ascending aorta establishes a dual-coronary system and is the goal of current surgical approaches. We report the development of our surgical technique for ALCAPA. METHODS: Between September 1993 and December 2000, 13 patients underwent surgery for ALCAPA. There were four males and nine females. Ages ranged from 1 month to 25 years (median=3.9) and weight ranged from 2.6 to 102kg (median=16.8). One patient had previously undergone an operative procedure at an outside institution. RESULTS: Direct implantation of the anomalous coronary artery into the ascending aorta was feasible in 12 of 13 patients. In situ transfer was performed in one patient with an intramural coronary artery. The first case in the series required an intrapulmonary baffle reconstruction (Takeuchi procedure) because the coronary artery arose remotely from the ascending aorta from the left-anterior sinus of the PA. For coronary transfer, a trapdoor flap was created on the ascending aorta for the implantation of the coronary button and the sinus defect in the main PA was augmented with a pericardial patch. The left ventricular (LV) shortening fraction was improved from a median value of 27% (range 12-36%) preoperatively to 33% (range 24-45%) in the immediate postoperative period (P=0.004). The LV end-diastolic dimension decreased from a median value of 36 mm (range 22-70 mm) preoperatively to 29 mm (range 19-56 mm) in the immediate postoperative period (P=0.004). There has been no mortality or reoperation during a median follow-up of 36 months. CONCLUSIONS: Using a standard technique, direct implantation of the anomalous coronary artery into the ascending aorta was achieved in all cases but one. At intermediate follow-up, LV function had improved by echocardiography. No postoperative mechanical circulatory support was required in any of these patients. This operative technique is reproducible and is applicable to the majority of patients with ALCAPA.[Abstract] [Full Text] [Related] [New Search]