These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Variable day/night bias in 24-h non-invasive finger pressure against intrabrachial artery pressure is removed by waveform filtering and level correction. Author: Westerhof BE, Guelen I, Parati G, Groppelli A, van Montfrans GA, Wieling W, Wesseling KH, Bos WJ. Journal: J Hypertens; 2002 Oct; 20(10):1981-6. PubMed ID: 12359976. Abstract: BACKGROUND Twenty-four-hour finger arterial pressure (FAP) recordings show a negative bias against intrabrachial artery pressure (BAP) and the bias is greater during the night, thereby overestimating the nocturnal blood pressure dip. We have available a methodology with which to reconstruct BAP from FAP by waveform filtering (transfer function) and generalized level (bias) correction that reduces the bias for short-term blood pressure records. OBJECTIVE To investigate if this methodology also decreases the extra bias during the night, thereby yielding a better estimate of the nocturnal dip. METHODS Twenty-four-hour FAP and BAP blood pressure recordings were simultaneously obtained in eight healthy normotensive volunteers and 14 patients with hypertension (ages 19-60 years), during standardized scheduled activities. The data were analysed off-line, applying the brachial reconstruction technique (reBAP) consisting of a waveform filter and level correction. Simultaneous beats yielded systolic, diastolic and mean pressures that were averaged per 30 min, per day, per night, per activity, over the 24-h period, and for volunteers and patients separately. RESULTS Over the full 24 h, FAP systolic, diastolic and mean values for the total group differed from BAP by +1 +/- 10, -8 +/- 7 and -10 +/- 8 mmHg (mean +/- SD), respectively. Similarly, reBAPs differed by +1 +/- 11, -2 +/- 7 and -2 +/- 7 mmHg. BAPs dipped by 20 +/- 8, 13 +/- 6 and 15 +/- 6 mmHg, respectively, during the night. These dips were overestimated by +8, +4 and +4 mmHg by FAP, but not by reBAP: -1, +1 and +1 mmHg. The volunteer and the patient groups showed slight differences in results, but these were not statistically significant. CONCLUSIONS The generalized reconstruction technique to obtain near-brachial pressure from non-invasive FAP almost completely removed bias over the full 24-h day-night period and improved tracking of diurnal changes for all three blood pressure values.[Abstract] [Full Text] [Related] [New Search]