These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of an ionic compared to a non-ionic X-ray contrast agent on platelets and coagulation during diagnostic cardiac catheterisation. Author: Jung F, Spitzer SG, Pindur G. Journal: Pathophysiol Haemost Thromb; 2002; 32(3):121-6. PubMed ID: 12372925. Abstract: The aim of the present study was to evaluate the effects of ionic (ioxaglate) and non-ionic (iopromide) contrast media on haemostatic parameters ex vivo. In 40 patients undergoing coronary angiography, platelet function (platelet reactivity and serotonin concentration) and coagulation markers [thrombin-antithrombin III complexes, prothrombin fragments (F1+2) and the D-dimers] were measured. The use of an ionic X-ray contrast agent (XCA) (ioxaglate) in diagnostic cardiac catheterisation angiography is associated with lower thrombin generation and lower activation of the platelet system than when a non-ionic XCA is employed (iopromide). The results thus confirm the results of various in vitro studies and animal investigations.[Abstract] [Full Text] [Related] [New Search]