These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: LC-MS/MS determination of a farnesyl transferase inhibitor in human plasma and urine.
    Author: DePuy ME, Musson DG, Yu S, Fisher AL.
    Journal: J Pharm Biomed Anal; 2002 Nov 07; 30(4):1157-71. PubMed ID: 12408906.
    Abstract:
    To support clinical pharmacokinetic studies in cancer patients, sensitive and specific methods for measuring 4-[1-(4-cyanobenzyl)-5-imidazolylmethyl]-1-(3-chlorophenyl) piperazinone (I), a farnesyl transferase inhibitor (FTI), in human plasma and urine were developed and validated. The methods are based on high-performance liquid chromatography (HPLC) with atmospheric pressure chemical ionization (APCI) and tandem mass spectrometric (MS/MS) detection in the positive ion mode using a heated nebulizer interface. Drug and internal standard were isolated from plasma or basified urine using automated solid-phase extraction on cyano cartridges. The organic extracts were dried, reconstituted in aqueous acetonitrile and injected into the system. Chromatographic separation of I and internal standard (IS) was achieved using a BDS Hypersil C8 analytical column, with a mobile phase consisting of acetonitrile:methanol:water (50:4:46) and trifluoroacetic acid (0.05%) at a flow rate of 0.6 ml/min. MS/MS detection was performed on a PE-Sciex API 300 tandem mass spectrometer operated in selected reaction monitoring mode. The parent-->product ions monitored were m/z 406-->195 for analyte I and m/z 448-->195 for the internal standard. Unusual in this method is that quantitation is accomplished using a secondary product ion, m/z 195, of drug I and IS. The assays were validated over the concentration range of 0.5-1000 ng/ml (1.2 nM to 2.5 microM, respectively) in plasma, and 2.5-500 ng/ml (6.2 nM to 1.23 microM) in urine. Accuracy was within +/-10% of nominal concentration at all levels in urine, and all but the lowest standard in plasma (+/-14% at 0.5 ng/ml). Intraday precision (expressed as coefficients of variation, CVs) for standard replicates and interday precision for quality control (QC) samples were less than 8% at all concentrations in both matrices. Detailed descriptions of the extraction procedure and analytical methodology used in the assay of I in plasma and urine are presented. This procedure may have utility in the quantitation of other imidazole-based FTIs with cyanobenzyl substructures.
    [Abstract] [Full Text] [Related] [New Search]