These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Changes in heart rate and blood pressure under push pull maneuver simulated on a tilt table].
    Author: Chen TX, Wang L, Sun SZ, Wang LJ, Lei Z, Jiang SQ.
    Journal: Space Med Med Eng (Beijing); 2002 Aug; 15(4):307-8. PubMed ID: 12425341.
    Abstract:
    Objective. Push-pull maneuver (PPM) was simulated using a tilt table to assess detailed cardiovascular responses and the simulation model. Method. Ten healthy fighter pilots were exposed to 3 times transition of body position of head-up tilt (HUT) for 1 min-->head-down tilt (HDT) for 10 s, 15 s and 20 s respectively-->HUT for 1 min in randomized sequences. The rate of tilt table rotation was 45 degrees /s. Heart-level arterial blood pressure was monitored with 4 s intervals, and HR was continuously monitored by ECG. Result. HR and BP fell significantly during HDT compared with those during HUT; upon subsequent HUT, HR and BP were significantly less than those during previous HUT, except BP at 11-15 s. Conclusion. Cardiovascular responses to PPM can be simulated with a tilt table. It is suggested that the tilt table model is valid in simulating the PPM.
    [Abstract] [Full Text] [Related] [New Search]