These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Combined stimulation of adrenocorticotropin and compound-S by single dose metyrapone test as an outpatient procedure to assess hypothalamic-pituitary-adrenal function. Author: Berneis K, Staub JJ, Gessler A, Meier C, Girard J, Müller B. Journal: J Clin Endocrinol Metab; 2002 Dec; 87(12):5470-5. PubMed ID: 12466339. Abstract: The metyrapone test is used to test the hypothalamic-pituitary-adrenocortical axis. The present study aims to assess the diagnostic accuracy of combined stimulation of ACTH and compound-S (CMP-S). In addition, we analyzed the safety and practicability of this test as an outpatient procedure. A total of 327 metyrapone tests were analyzed retrospectively in 185 patients (mean age, 50.3 +/- 15.2 yr). One hundred thirteen patients had one test, and 72 patients had between 2 and 6 tests over 1-3 yr. Most patients suffered from pituitary adenomas (60 macroadenomas, 63 microadenomas) or other pituitary lesions (n = 29). Metyrapone (2 g) was given at 2400 h as an outpatient procedure. Blood samples for analysis of ACTH, CMP-S, and cortisol were taken at 0730 h. Stimulation of adrenal CMP-S and cortisol by pituitary ACTH demonstrated a dose-response curve with the shape of half a geometric parabola. CMP-S reached a plateau when ACTH rose above 175 ng/liter [r = 0.661, P < 0.0001 for ACTH <175 ng/liter; r = 0.083, P = not significant (NS) for ACTH >175 ng/liter], cortisol flattened at ACTH levels above 230 ng/liter (r = 0.633; P < 0.0001 for ACTH < 230 ng/liter; P = NS for ACTH >230 ng/liter). Alternatively, the sum of CMP-S plus cortisol also flattened when ACTH rose above 230 ng/liter (r = 0.696; P < 0.0001 for ACTH <230; P = NS for ACTH > 230 ng/liter). Receiver operating curve analysis defining a cut-off for ACTH at 150 ng/liter demonstrated a sensitivity of 47% and 67% at a cut-off level for CMP-S at 200 or 260 nmol/liter, respectively. The respective specificity was 82% and 68% for CMP-S. This compared with a sensitivity of 71% and specificity of 69% if the sum of CMP-S plus cortisol of 450 nmol/liter were used as cut-off. The response curve between CMP-S and ACTH implies a maximally stimulated adrenal cortex at circulating ACTH levels above 175 ng/liter. Single measurement of CMP-S using the cut-off at 200 nmol/liter, as suggested in the literature, yields a poor sensitivity of only 47% compared with ACTH. Despite the relatively high cross-reactivity of CMP-S in the cortisol assay, the sum of CMP-S and cortisol levels with a cut-off value of 450 nmol/liter yields a better diagnostic accuracy compared with CMP-S alone.[Abstract] [Full Text] [Related] [New Search]