These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Heparin versus danaparoid in off-pump coronary bypass grafting: results of a prospective randomized clinical trial. Author: Carrier M, Robitaille D, Perrault LP, Pellerin M, Pagé P, Cartier R, Bouchard D. Journal: J Thorac Cardiovasc Surg; 2003 Feb; 125(2):325-9. PubMed ID: 12579101. Abstract: OBJECTIVE: The incidence of heparin-induced thrombocytopenia is increasing, and the thrombin inhibitor danaparoid could be a useful alternative. The objective of the present study was to compare danaparoid and heparin in patients undergoing off-pump coronary artery bypass grafting. METHODS: In a prospective, randomized, double-blind clinical trial comparing heparin (bolus of 1 mg/kg) with danaparoid (bolus of 40 U/kg), 71 patients underwent off-pump coronary artery bypass grafting with one of the study drugs. The amount of blood lost, the number of homologous blood products transfused, the troponin T levels, and the amount of anti-Xa activity were monitored. RESULTS: Thirty-four patients underwent 2.6 +/- 0.7 bypasses with danaparoid, and 37 patients underwent 2.5 +/- 0.9 grafts with heparin (P =.8). Postoperative blood losses averaged 1394 +/- 1033 mL in patients receiving danaparoid and 1130 +/- 868 mL in patients receiving heparin (P =.2). The number of homologous blood products transfused averaged 3.6 +/- 7 units in patients receiving danaparoid and 1.9 +/- 4.4 units in patients receiving heparin (P =.2). The number of patients requiring homologous blood transfusion was higher in patients receiving danaparoid (18/34 [53%]) than in patients receiving heparin (10/37 [27%], P =.03). Serum anti-Xa activity averaged 1.6 +/- 0.6 U/mL in patients receiving danaparoid and 1.9 +/- 0.8 U/mL in patients receiving heparin 30 minutes after injection of the drugs (P =.1) and 0.3 +/- 0.1 and 0.04 +/- 0.08 U/mL, respectively, 12 hours after coronary artery bypass grafting (P =.001). Troponin serum levels were similar 48 hours after coronary artery bypass grafting (0.5 +/- 0.6 and 0.4 +/- 0.6 microg/L, respectively). CONCLUSION: Although off-pump coronary artery bypass grafting with danaparoid versus heparin increases the number of patients exposed to homologous blood transfusion (relative risk, 2; 95% confidence limits, 1-4), off-pump coronary artery bypass grafting with danaparoid is a valuable alternative to heparin in patients with thrombocytopenia requiring surgical intervention.[Abstract] [Full Text] [Related] [New Search]