These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output.
    Author: Haryadi DG, Orr JA, Kuck K, McJames S, Westenskow DR.
    Journal: J Clin Monit Comput; 2000; 16(5-6):361-74. PubMed ID: 12580219.
    Abstract:
    OBJECTIVE: Evaluation in animals of a non-invasive and continuous cardiac output monitoring system based on partial carbon-dioxide (CO2) rebreathing indirect Fick technique. METHODS: We have developed a non-invasive cardiac output (NICO) monitoring system, based on the partial rebreathing method. The partial rebreathing technique employs a differential form of the Fick equation for calculating cardiac output (QT) using non-invasive measurements. Changes in CO2 elimination (deltaVCO2) and partial pressure of end-tidal CO2 (deltaPETCO2) in response to a brief period of partial rebreathing are used to measure pulmonary capillary blood flow (Q(PCBF)). A non-invasive estimate of anatomic and intrapulmonary shunt fraction (Q(S)/Q(T)), based on oxygen saturation from pulse oximetry (SpO2) and inspired oxygen concentration (FIO2), is added to compute total cardiac output [Q(T) = Q(PCBF)/(1 - Q(S)/Q(T))]. The performance of the NICO was compared with iced 5% dextrose bolus thermodilution cardiac output (TDco) measurements in 6 dogs. Cardiac output was varied using dobutamine, and halothane, and by clamping of the inferior vena cava. Two hundred and forty-six (n = 246) paired measurements of TDco and NICO over a range of cardiac outputs (TDco range = 0.60-8.87 l/min) were compared using Bland-Altman analysis and weighted correlation coefficient. RESULTS: The Bland-Altman technique yielded a NICO precision of +/- 0.70 l/min (13.8%) with a mean bias of -0.07 l/min (-1.4%) compared to TDco. The weighted correlation coefficient between TDco and NICO values was: r = 0.93 (n = 246). CONCLUSION: The partial CO2 rebreathing technique for measurement of cardiac output is non-invasive, automated, and based on the well accepted Fick principle. The limits of agreement between NICO and TDco is within the recommended value for NICO to be a clinically acceptable method for cardiac output measurement. The results of this canine study show that NICO performed as well, and in some cases better, than other currently available non-invasive cardiac output techniques over a wide range of cardiac outputs.
    [Abstract] [Full Text] [Related] [New Search]