These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Poor results with the Shuttle Stop: resorbable versus nonresorbable intramedullar cement restrictor in a prospective and randomized study with a 2-year follow-up.
    Author: Freund KG, Herold N, Røck ND, Riegels-Nielsen P.
    Journal: Acta Orthop Scand; 2003 Feb; 74(1):37-41. PubMed ID: 12635790.
    Abstract:
    In a randomized prospective study we compared 2 femoral plugs as regards probable migration of the restrictor, cement leakage and possible early aseptic loosening. In group I, the femoral canal was plugged with a resorbable Shuttle Stop (HC Implants, BV. Leiden, The Netherlands). In group II, a nonresorbable restrictor of polyethylene was used (De Puy, UK). Both groups were identical as regards age, gender and primary disease. All patients were followed for at least 2 years after surgery. Postoperatively, we found more failures with displacement of the femoral plug and cement leakage in group I than in group II. At the 2-year follow-up, we found no differences in stem loosening or grade of radiolucent lines in the cement-bone interface. We can not recommend the Shuttle Stop for femoral canal sealing in total hip replacememt.
    [Abstract] [Full Text] [Related] [New Search]