These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Improving planning procedure in brain biopsy: coupling frame-based stereotaxy with navigational device STP 4.0.
    Author: Winkler D, Trantakis C, Lindner D, Richter A, Schober J, Meixensberger J.
    Journal: Minim Invasive Neurosurg; 2003 Feb; 46(1):37-40. PubMed ID: 12640582.
    Abstract:
    37 consecutive patients with space-occupying intracerebral lesions were operated via frame-based stereotaxy. After CT-localizing of suspect lesions and computer-supported definition of entry and target coordinates a serial stereotactic biopsy was performed. Biopsy specimens allowed a satisfactory neuropathological examination and diagnostic result in 36 cases (97 %). Only three patients (8.1 %) showed an intraoperative bleeding, which was not associated with any postoperative CT-detectable hematoma, neurosurgical intervention nor with any neurological deficits. In summary we described the method of a computerized planning technique for stereotactic biopsy with the use of a special stereotactic planning program. High percentage of satisfactory neuropathological diagnoses and comfortable and accurate definition of target and entry coordinates justify computer support as a routine method.
    [Abstract] [Full Text] [Related] [New Search]