These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement. Author: Shi YB, Binette M, Martin WH, Pearson JM, Hart RA. Journal: Spine (Phila Pa 1976); 2003 Mar 15; 28(6):595-601. PubMed ID: 12642768. Abstract: STUDY DESIGN: Thoracic pedicle screws were stimulated electrically while recording electromyography (EMG) activity in associated muscle groups intraoperatively. Screw position was then evaluated after surgery using computed tomography (CT). The CT results were compared with evoked EMG threshold values. OBJECTIVE: To report our experience with pedicle screw stimulation in thoracic vertebrae in 22 patients who underwent thoracic level spinal instrumentation from May 1999 to March 2001. SUMMARY OF BACKGROUND DATA: Pedicle screw stimulation for intraoperative assessment of screw placement has been reported in lumbosacral spinal procedures. Evoked EMG thresholds >10 or 11 mA are associated with increased probability of vertebral cortex violation and postoperative complications. Thresholds >15 mA provide a 98% confidence of accurate screw positioning on postoperative CT scans. METHODS: Evoked EMG activity was recorded from ulnar carpal flexors, intercostals, or abdominal muscle groups, depending on the level of screw placement. Postoperative CT scans were read by a staff orthopedic spine surgeon, a senior resident in orthopedics, and a musculoskeletal radiologist. RESULTS: Results of 87 screws are reported. Five screws (5.7%) showed penetration on postoperative CT scans. Six screws (6.9%) had stimulation thresholds < or =11 mA, of which three showed cortical breakthrough. Of the 81 screws with thresholds >11 mA, 79 (97.5%) were within the vertebra. No postoperative neurologic complications were noted in any of the 22 patients. CONCLUSION: These results are consistent with previous studies of lumbosacral pedicle screws. In this series, stimulation thresholds >11 mA have a 97.5% negative predictive value, suggesting that cortical violation is highly unlikely. Although judgment of screw placement should not depend solely on stimulation thresholds, pedicle screw stimulation may provide rapid and useful intraoperative information on screw placement during procedures involving the use of thoracic pedicle screws.[Abstract] [Full Text] [Related] [New Search]