These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Biomechanical analysis of the lumbar spine with anterior interbody fusion on the different locations of the bone grafts.
    Author: Cheng CK, Chen CS, Liu CL.
    Journal: Biomed Mater Eng; 2002; 12(4):367-74. PubMed ID: 12652031.
    Abstract:
    The anterior lumbar interbody fusion is the common procedure in the management of the degenerated disc in the lumbar spine, but the biomechanical behavior of the fused segment would be changed because of the implantation of bone graft at the different locations. To investigate the biomechanical alteration, the study applied the finite element model to undergo the stress analysis.A three-dimensional finite element model of the lumbar spine was established, and modified to the three fusion models consisted of the bone graft at the anterior site, the middle site and the posterior site, respectively. The 12 N m flexion and the 10 N m torsion with pre-load 150 N were imposed on the L1 vertebral body. The results of the finite element model indicated that placing bone graft at anterior site could effectively resist flexion moment, and decreased the tensile force of the posterior ligaments about 15% above. Placing bone graft at posterior site could resist torsional moment, and also led to none of contact force of the facet joint in the fused segment. However, wherever the bone grafts were placed, stress slightly increased on the disc adjacent to interbody fusion about 5% below.
    [Abstract] [Full Text] [Related] [New Search]