These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A specific radioimmunoassay for PGE2 using an antibody with high specificity and a sephadex LH-20 microcolumn for the separation of prostaglandins. Author: Christensen P, Leyssac PP. Journal: Prostaglandins; 1976 Feb; 11(2):399-420. PubMed ID: 1265299. Abstract: Antiserum against PGE2 was raised in rabbits following immunization with prostaglandin-hen-gamma-globulin conjugate. The antiserum exhibited 14% cross reactivity with PGE1 and far less cross-reaction with heterologous prostaglandins. A microcolumn of Sephadex LH-20 was used for a partial, but sufficient separation of PGE2 from PGE1 and a complete separation from heterologous prostaglandins to ensure a specific RIA for PGE2. The precision of the method in the rage 10-500 picograms showed a coefficient of variation varying between 4 and 13%. The detection limit was 10 picograms corresponding to 15 pg/ml of PGE2 in serum. In order to demonstrate the validity of the method values obtained for non-diuretic rat renal venous serum were compared with those obtained using the isotope derivative method of Bojesen & Buckhave (1972) on the same samples. The concentrations of PGE2 obtained were 239 +/- 25 pg/ml and 250 +/- 58 pg/ml, respectively.[Abstract] [Full Text] [Related] [New Search]