These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: The effect of design modifications on the torsional and compressive rigidity of U-shaped palatal major connectors. Author: Green LK, Hondrum SO. Journal: J Prosthet Dent; 2003 Apr; 89(4):400-7. PubMed ID: 12690354. Abstract: STATEMENT OF PROBLEM: Rigidity is a requirement of removable partial denture frameworks. Although commonly used by dentists, the U-shaped (horseshoe) maxillary major connector lacks the rigidity of other maxillary major connector designs. PURPOSE: The purpose of this study was to determine the effects of changing width, thickness, and shape on the rigidity of U-shaped maxillary major connectors. MATERIAL AND METHODS: Five nickel-chrome alloy frameworks were fabricated from the same master cast for each of 4 different U-shape removable partial denture designs. The designs were an 8-mm wide U-shaped strap with a 6-mm posterior strap (A-P strap), a 13-mm-wide U-shape strap (Wide), an 8-mm-wide U-shape strap that widened to 13 mm at the midline (Notch), and an 8-mm-wide U-shaped strap that was twice the thickness of the other straps (Thick). A fifth group of 5 frameworks was made by removing the posterior strap from the A-P strap frameworks (A strap). Two testing points were marked on each framework corresponding to the first premolar and second molar positions. The frameworks were mounted in a universal testing machine, and vertical (torsional) and horizontal (compressive) loads were applied using a 10-kN load cell at a cross-head speed of 2 mm/min until a deflection of 1 mm occurred. A force-deflection curve was generated for each test, and slope of the curves (N/mm) was compared with analysis of variance and Scheffe's F test (alpha=0.05). RESULTS: The Thick group was found to be significantly more rigid (P<.05) than the other frameworks when torsional loads were applied to both the premolar (22.42 N/mm) and molar (10.88 N/mm) areas, and when a compressive load was applied to the premolar (232.85 N/mm) area. The A-P strap group was significantly more rigid (P< or =.05) than the other designs when a compressive load was applied to the molar (69.56 N/mm) area. Both the Thick and A-P strap groups were significantly more rigid (P<.05) than the Notch and A strap groups in all tests. CONCLUSION: Doubling the thickness of the anterior strap of a U-shaped maxillary major connector improved the rigidity of the framework to torsional loads. A posterior strap became more effective in maintaining framework rigidity to compressive forces as the length of the arch increased.[Abstract] [Full Text] [Related] [New Search]