These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Orthogonal view analysis for evaluating the femoral component position of total hip implants in dogs using postoperative radiographs. Author: Jehn CT, Bergh MS, Manley PA. Journal: Vet Surg; 2003; 32(2):134-41. PubMed ID: 12692758. Abstract: OBJECTIVE: To show the ability to obtain repeatable, accurate, quantitative data to assess the position of the femoral component of canine total hip implants using postoperative radiographs. STUDY DESIGN: Cadaveric study and clinical trial. ANIMALS: Five cadaveric canine femurs and 4 patients. METHODS: Femoral implants were placed into 5 cadaveric canine femurs in predetermined locations. Orthogonal radiographs were taken of each femur at 10 degrees intervals as they were moved through a natural range of hip motion. An assessment of implant position was made with each set of radiographs and analyzed to observe significant inconsistencies in the values obtained when the femur was repositioned. Three investigators positioned and radiographed the hips of 4 client-owned dogs that had total hip arthroplasty (THA). Each investigator obtained a set of orthogonal radiographic views from which implant position was measured. The measurements obtained from each investigator's set of radiographs were statistically analyzed to evaluate for interobserver differences. RESULTS: The methods described indicate that consistent data regarding femoral implant placement can be obtained from postoperative radiographs of THA patients. Under most circumstances, change in position of the femur did not significantly affect femoral implant measurements. There were no significant differences noted among values obtained by different investigators. CONCLUSIONS: Measurements based on the femoral and implant axes obtained from orthogonal radiographic views of the femur provide a means for obtaining accurate and consistent quantitative data regarding femoral implant position using postoperative radiographs of canine THA patients. CLINICAL RELEVANCE: Acquisition of quantitative information about femoral implant position using postoperative radiographs will facilitate development of a readily available data source. This information, attainable in a clinical setting, may help identify elements of implant position that are important in determining the clinical outcome of THA in dogs.[Abstract] [Full Text] [Related] [New Search]