These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Guidewire damage during cannulated screw fixation for slipped capital femoral epiphysis. Author: Robb JE, Annan IH, Macnicol MF. Journal: J Pediatr Orthop B; 2003 May; 12(3):219-21. PubMed ID: 12703039. Abstract: Cannulated screw fixation of slipped capital femoral epiphysis is a standard procedure for the mild to moderately displaced slip. We report six cases in which the guidewire was damaged by a cannulated drill. In five the wire broke off within the femur. The broken wire was retrieved in two of the cases but not in the remaining three. The progress of all six patients was unaffected by this complication.[Abstract] [Full Text] [Related] [New Search]