These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Extra-large press-fit cups without screws for acetabular revision. Author: Obenaus C, Winkler H, Girtler R, Huber M, Schwägerl W. Journal: J Arthroplasty; 2003 Apr; 18(3):271-7. PubMed ID: 12728417. Abstract: This retrospective study reports the 4- to 6-year results of clinical and radiologic follow-up of 60 acetabular revisions using extra-large hemispherical press-fit cups without additional screw fixation. Bone grafts were used in 17 cases. One cup loosened and required re-revision after 12 months. Initial migration was noted in 6 cases, but showed no progression after less than 2 years. In 2 hips that were revised for deep infection, the cups were found incorporated. At final follow-up, 57 hips (95%) were found firmly fixed radiologically. The Harris Hip score improved from a mean of 58.7 points preoperatively to 90.6 points. Provided a high friction coefficient is present, extra-large hemispherical cups offer sufficient stability even in severe cases. Most do not require additional screw fixation.[Abstract] [Full Text] [Related] [New Search]