These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Asbestos release during removal of resilient floor covering materials by recommended work practices of the resilient floor covering institute. Author: Williams MG, Crossman RN. Journal: Appl Occup Environ Hyg; 2003 Jun; 18(6):466-78. PubMed ID: 12746067. Abstract: The release of asbestos during maintenance and removal of resilient floor covering is of concern to health professionals and many regulators. This study assesses the asbestos levels observed during removal of resilient floor covering products using the "Recommended Work Practices" (1995) of the Resilient Floor Covering Institute or other methods requiring containment (Controls). The 1995 "work practices" require wet removal or dry heat removal but do not require the use of respirators. Wet removals of sheet vinyl/separated backing, 12" x 12" vinyl asbestos tile/mastic, and 9" x 9" asphalt tiles/mastic were conducted and the air was sampled during each procedure. Settled dust samples were collected at the sites of RFCI square tile removal and pieces of each type of tile were broken in a mini-enclosure to evaluate asbestos emissions. Analyses of the air samples collected during the removals showed that the RFCI methods did not produce asbestos counts significantly different from the Control methods requiring containment. Only a small number (0.7%) of fibers and structures, counted and measured by Analytical Transmission Electron Microscopy, would have been counted using the rules for Phase Contrast Microscopy in the 7400 method specified by Occupational Safety and Health Administration regulations. This indicates workers in similar situations without respirators are likely to have unknown exposure levels. A high percentage of these fibers and structures are 5 micrometers or less in length, smaller than 0.5 micrometer in diameter, and are easily inhaled. The RFCI air sample and settled dust data may cause regulators to consider requiring respiratory protection, cleanup procedures, and methods to control asbestos migration. Other areas that might be addressed are clearance levels and their measurement, removal area size, bulk sample analysis by transmission electron microscopy if polarized light microscopy reports less than 1 percent asbestos, better worker exposure evaluation, and supervisor/worker training in accordance with the Model Accreditation Plan.[Abstract] [Full Text] [Related] [New Search]