These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Use of WuScope for exchange of endotracheal tube in a patient with difficult airway. Author: Sprung J, Wright LC, Dilger J. Journal: Laryngoscope; 2003 Jun; 113(6):1082-4. PubMed ID: 12782828. Abstract: OBJECTIVE: To describe a method for the exchange of a defective endotracheal tube using the WuScope in patients with difficult airways who cannot tolerate interrupted ventilation. STUDY DESIGN: Case report. METHODS: Detailed description of proposed modality for the endotracheal tube exchange. RESULTS: Exchanging a defective endotracheal tube in patients with a "difficult airway" and compromised oxygenation can be a challenging task. Performing fiberoptic visualization with the WuScope and using a "double intubation" technique may be an acceptable method for endotracheal tube exchange in some clinical situations. CONCLUSION: By using our technique the exchange of an endotracheal tube in a patient with a difficult airway may be achieved without interrupting the ventilation.[Abstract] [Full Text] [Related] [New Search]