These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Application of a flow-type antibody sensor to the detection of Escherichia coli in various foods. Author: Kim N, Park IS. Journal: Biosens Bioelectron; 2003 Aug 15; 18(9):1101-7. PubMed ID: 12788552. Abstract: A flow-type biosensor system which uses a broad-spectrum anti-Escherichia coli antibody and quartz crystal microbalance as biological component and transducer was developed. Biosensor responses were initiated by injecting viable E. coli suspensions through a flow cell and the sensor system was optimized for response time according to flow rate and injection time, followed by the measurement of responses for various E. coli strains. As expected, the sensor system showed a characteristic broad binding feature against E. coli strains. A linear sensor response in double-logarithmic scale was observed for the microbial suspensions ranging from 1.7 x 10(5) to 8.7 x 10(7) CFU/ml. Sample measurements could be done within 20-30 min after Stomacher treatment followed by spiking or enrichment.[Abstract] [Full Text] [Related] [New Search]