These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Shear resistance of silver- and stainless steel-reinforced glass-ionomer cements bonded to enamel and dentin. Author: Kerby RE. Journal: Int J Prosthodont; 1992; 5(5):469-74. PubMed ID: 1290578. Abstract: The shear bond strength to human dentin and enamel was evaluated for four glass-ionomer cements: an experimental stainless steel-reinforced glass-ionomer cement, two commercially available silver-reinforced cements, and a conventional glass-ionomer cement. Bonded specimens were stored in distilled water for 7 days during which time they were subjected to thermocycling in water baths at 5 degrees C and 55 degrees C for a 1-minute dwell time per bath and 1500 cycles. Specimens were then shear tested. The experimental stainless steel-reinforced glass-ionomer cement had a significantly higher bond strength to enamel (P < .01) and dentin (P < .05) than did the commercially available cements.[Abstract] [Full Text] [Related] [New Search]