These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Iatrogenic vertebral arteriovenous fistula treated with a hemobahn stent-graft.
    Author: Priestley R, Bray P, Bray A, Hunter J.
    Journal: J Endovasc Ther; 2003 Jun; 10(3):657-63. PubMed ID: 12932183.
    Abstract:
    PURPOSE: To illustrate the utility of color flow duplex ultrasound (CFDU) in the diagnosis and stent-graft treatment of a rare arteriovenous fistula (AVF) involving the vertebral artery and vein. CASE REPORT: An iatrogenic AVF involving the right vertebral artery and vein was diagnosed in a 45-year-old man using CFDU. Treatment was recommended due to the large volume of blood shunted through the fistula and the associated loud bruit. Endoluminal treatment involved deployment of a covered stent within the vertebral artery to exclude the fistula. Postoperative CFDU confirmed the success of the treatment. CONCLUSIONS: CFDU can be utilized to accurately diagnose unusual lesions, such as AVFs involving the vertebral artery. The technique is also useful in planning treatment and monitoring the durability of stent-grafts implanted to obliterate this type of defect.
    [Abstract] [Full Text] [Related] [New Search]