  • Title: [Determination of nickel in artificial cream by flame atomic absorption spectrometry].
    Author: Shen Z, Shen H.
    Journal: Guang Pu Xue Yu Guang Pu Fen Xi; 2001 Aug; 21(4):567-8. PubMed ID: 12945297.
    Abstract:
    This paper describes a new method for the determination of nickel in artificial cream by flame atomic absorption spectrometry. Compared with the others, the process of sample treatment by HNO3-H2SO4 is simple, and the operation is easy. The results show that the method offers good precision and accuracy. The relative standard deviation is 3.04% and the rate of recovery is 97.7%.