These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [The accuracy of placental scintigraphy (author's transl)].
    Author: Rothe R, Motzko M, Rexilus F, Heinze HG.
    Journal: Rofo; 1976 Mar; 124(3):271-4. PubMed ID: 131093.
    Abstract:
    The results of 150 placental scans are reported, using 99mTc erythrocytes, 113mIn gelatine and 113mIn tranferrin. Accuracy was checked at surgery and compared with ultra sound findings. In 62% of patients, the indications for placental scintigraphy was suspicion of placenta praevia because of bleeding in late pregnancy. In 38% placental localisation was performed for amniocentesis for Rh incompatibility. Localisation of the placenta was accomplished in 98.6% by scanning and in 95% by ultra sound. Accuracy of scanning was 94% and ultra sound 70%. Placental scanning is at present the most accurate method for a placental localisation and should therefore be used when an accurate diagnosis cannot be achieved by other techniques.
    [Abstract] [Full Text] [Related] [New Search]