Title: Electrodiagnosis reliability in the diagnosis of infant botulism. Author: Graf WD, Hays RM, Astley SJ, Mendelman PM. Journal: J Pediatr; 1992 May; 120(5):747-9. PubMed ID: 1315854. Abstract: Infant botulism is confirmed by isolation of Clostridium botulinum from stool culture or by toxin assay. Although electrodiagnosis has been described as a diagnostic tool in infant botulism, our 11-year review of toxin-confirmed cases suggests that electrodiagnosis is not a reliable tool. In the case report presented, results of electrodiagnosis were negative but enema effluent contained adequate concentrations of organism and toxin to confirm the diagnosis.[Abstract] [Full Text] [Related] [New Search]