These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Dacron arterio-venous interposition graft: an access to circulation in patients on chronic hemodialysis. Author: Jacob ET, Shapira Z, Boner G. Journal: Angiology; 1977 Jan; 28(1):31-5. PubMed ID: 141229. Abstract: In a small percentage of cases, conventional a-v fistulae of the Brescia-Cimino type fail to provide long-term access facilities for chronic hemodialysis. When homologous venous interposition grafts are not available, the surgeon is forced to seek foreign interposition material. In three instances woven dacron arterio-venous interposition grafts were successfully constructed in the thigh, and uneventful hemodialysis was accomplished in all 3 patients.[Abstract] [Full Text] [Related] [New Search]