These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: REPLACEMENT OF THE AORTIC AND MITRAL VALVES USING THE STARR-EDWARDS BALL-VALVE PROSTHESIS: A REPORT OF 50 CASES.
    Author: CALLAGHAN JC.
    Journal: Can Med Assoc J; 1964 Aug 29; 91(9):411-21. PubMed ID: 14179062.
    Abstract:
    The aortic and mitral valves were replaced in 50 patients at the University of Alberta Hospital using the Starr-Edwards ball-valve prosthesis. The basis of the selection of 20 patients for isolated aortic valve replacement and 27 for mitral valve replacement using this type of prosthesis is presented, and the techniques of insertion of the aortic and mitral valve are described in detail. Of the 27 patients in whom the mitral valve was replaced by the Starr-Edwards prosthesis six died within 30 days of surgery and two after discharge from hospital at two and a half and four months, respectively. Left atrial thrombosis was the cause of death in four of these patients. In 20 patients in whom the aortic valve was replaced, four died in hospital and two died more than 30 days after returning home. Three of these six patients died from bleeding-the result of the use of anticoagulants. The difficulty in assessing whether or not anticoagulants are needed following replacement by a Starr-Edwards prosthesis is considered. It is felt, in our present state of knowledge, that anticoagulants should be used following mitral valve replacement but are probably not essential following replacement of the aortic valve. Two patients survived replacement of both aortic and mitral valves and have been followed up 18 months and seven months, respectively.
    [Abstract] [Full Text] [Related] [New Search]