These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of methacrylonitrile in serum using gas chromatography and flame ionization detection.
    Author: Demby KB, White TC, Ghanayem BI.
    Journal: J Chromatogr; 1992 Aug 07; 579(1):153-7. PubMed ID: 1447342.
    Abstract:
    A gas chromatographic method is described for the quantitation of methacrylonitrile in serum. Methacrylonitrile was extracted from rat serum with diethyl ether and then quantified using a gas chromatograph equipped with a flame ionization detector and a 60-m megabore column coated with polyethylene glycol polymer. The recoveries obtained following a one-step extraction with diethyl ether varied from 60% at 3.2 micrograms/ml to 70% at 80 micrograms/ml. The coefficient of variation for the analysis ranged from 2.5% at 400 micrograms/ml to 15.0% at 3.2 micrograms/ml.
    [Abstract] [Full Text] [Related] [New Search]