These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Albuterol aerosol delivered via metered-dose inhaler to intubated pediatric models of 3 ages, with 4 spacer designs. Author: Mandhane P, Zuberbuhler P, Lange CF, Finlay WH. Journal: Respir Care; 2003 Oct; 48(10):948-55. PubMed ID: 14525631. Abstract: OBJECTIVE: To determine the amount of albuterol, in various particle size ranges, delivered from a hydrofluoroalkane-propelled metered-dose inhaler (Airomir) in 3 models of pediatric intubation (ages 8 months, 4 years, and 16 years) using 4 types of aerosol reservoir: 3 spacers (ACE, AeroChamber HC MV, metal NebuChamber without 1-way valve) and 1 holding chamber (metal NebuChamber with 1-way valve). METHODS: Five reservoirs of each type were tested with albuterol sulfate delivered via metered-dose inhaler that delivers 100 microg of albuterol per actuation. Each reservoir was connected to an endotracheal tube (ETT) that corresponded to the given patient age (8 months = 4 French; 4 years = 5 French; 16 years = 7.5 French) and to a valved system that allowed connection of the ETT to a cascade impactor. Simulated tidal volumes representative of children of the given ages were passed through the reservoir. Both the cascade impactor and the ETT were enclosed within a 100% humidity, 37 degrees C environment. RESULTS: For the total amount of albuterol inhaled onto the impactor, and both the 1.1-4.7 microm and 1.1-3.3 microm inhaled fine-particle fractions, the NebuChamber-with-valve showed significantly greater drug delivery than the NebuChamber-without-valve, the AeroChamber HC MV, or the ACE (p < 0.001). Among the reservoirs without valves the NebuChamber showed significantly greater delivery than the AeroChamber HC MV or ACE (p < 0.001) for total drug deposition and for both the 1.1-4.7 microm and 1.1-3.3 microm fine-particle fractions. These results were consistent over all age groups. The AeroChamber HC MV had significantly greater delivery (total deposition) than the ACE (p < 0.001), except in the 4-year-old model. There were no significant differences between the AeroChamber HC MV and the ACE for either the 1.1-4.7 microm or the 1.1-3.3 microm fine-particle fraction. CONCLUSION: An aerosol reservoir with 1-way valve positioned between the spacer and the ETT improved the amount of inhaled albuterol 300-900%, compared to the other reservoirs.[Abstract] [Full Text] [Related] [New Search]