These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of picogram levels of heptylphysostigmine in human plasma using high-performance liquid chromatography with fluorescence detection. Author: Herold ML, Constanzer ML, Matuszewski BK. Journal: J Chromatogr; 1992 Oct 23; 581(2):227-36. PubMed ID: 1452613. Abstract: A sensitive (50 pg/ml) method for the determination of heptylphysostigmine in human plasma is described. The procedure is based on liquid-liquid extraction of the drug from buffered plasma, and analysis of the concentrated organic extract using high-performance liquid chromatography on a silica column, under normal-phase chromatographic conditions, with fluorescence detection. Physostigmine was used as an internal standard. The assay has been fully validated in the concentration range 50-2000 pg/ml and utilized for the analysis of clinical samples from subjects dosed with heptylphysostigmine.[Abstract] [Full Text] [Related] [New Search]