These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Long-term evaluation of paclitaxel-coated stents for treatment of native coronary lesions. First results of both the clinical and angiographic 18 month follow-up of TAXUS I. Author: Büllesfeld L, Gerckens U, Müller R, Grube E. Journal: Z Kardiol; 2003 Oct; 92(10):825-32. PubMed ID: 14579046. Abstract: The development of restenoses due to tissue proliferation within the stented segment is a major limitation of conventional stent implantations. Recently published studies have shown that drug-eluting stents effectively decrease the incidence of stent restenosis at 6 month follow-up as compared to bare metal stents. However, a persistent efficacy of this stent design beyond the 6 month period still needs to be proven. Therefore, in this study, we are demonstrating the first 18 month follow-up results of a Paclitaxel-coated coronary stent, based on the patient population of the TAXUS I study, a multicenter randomized study to evaluate both safety and efficacy of the Paclitaxel-coated NIRx stent as compared to an uncoated, bare metal stent. In this study we evaluated the long-term outcome of NIRx patients of our center, in which 20 out of 31 patients of the TAXUS I study with NIRx stent implantation have been enrolled. A clinical follow-up was available in 20 out of 20 patients (100%) 535 +/- 82 days post stent implantation (17.8 months). An angiographic follow-up was available in 14 out of 20 patients (70%) 580 +/- 77 days post stent implantation (19.1 months). The MACE rate at 18 month follow-up was 0.0%. There was no stent restenosis in the study group up to 18 month post drug-eluting stent implantation. There was one non-clinically driven target vessel revascularization due to a stent edge lumen renarrowing, which was subsequently calculated as a 43% diameter stenosis. Accordingly, this event was not regarded as MACE. The IVUS analysis of the study population has shown a decrease of the mean minimum lumen area from 8.45 mm(2) postinterventional to 6.87 mm(2) at 6 month follow-up with a relative mean maximum plaque area of 16%. At 18 month follow-up, there were no additional significant changes with a mean minimum lumen area of 7.16 mm(2) and a relative mean maximum plaque area of 13.4%. The reported results of the 18 month follow-up of TAXUS I are the first experiences demonstrating a persistent benefit of the Paclitaxel-coated NIRx stent. Therefore, this stent design seems to be safe and effective, even in long-term follow-up.[Abstract] [Full Text] [Related] [New Search]