Search MEDLINE/PubMed
Title: [Clinical significance of correcting the serum level of phenytoin according to the albuminaemia in hospitalized patients and outpatients]. Author: Hermida-Ameijeiras J, Montero-Furelos C, Tutor-Valcarce JC. Journal: Rev Neurol; ; 37(10):909-12. PubMed ID: 14634917. Abstract: INTRODUCTION: It has recently been reported that in developing countries, which have a high prevalence rate of hypoalbuminaemia, the total concentration of phenytoin in serum would often provide incorrect clinical information. PATIENTS AND METHODS: The serum levels of phenytoin and albumin were determined in 400 adult patients of both sexes (231 hospitalized and 169 outpatients) attended in our hospital, and the concentrations of the drug were corrected using the Sheiner Tozer equation (STE). RESULTS: A clinically significant difference between the corrected and experimental concentrations of phenytoin (< 1.2 mg/L) was found in 74.4% of the hospitalized patients and in 21.3% of the outpatients. CONCLUSIONS: According to these findings and given the fact that determining the concentration of free phenytoin (i.e. not linked to albumin) is not routinely carried out, we recommend the systematic correction of phenytoin levels in our community in order to better adjust dosages. The possible limitations of the use of STE for standardizing phenytoin concentrations are also discussed.[Abstract] [Full Text] [Related] [New Search]