These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Endolaryngeal extrusion of expanded polytetrafluoroethylene implant after medialization thyroplasty. Author: Laccourreye O, Hans S. Journal: Ann Otol Rhinol Laryngol; 2003 Nov; 112(11):962-4. PubMed ID: 14653365. Abstract: Various nonresorbable implants are currently used worldwide for medialization thyroplasty in patients with unilateral vocal cord paralysis. The Gore-Tex (expanded polytetrafluoroethylene) implant was introduced in the late 1990s. At our institution, 27 patients with unilateral laryngeal nerve paralysis had medialization thyroplasty with a Gore-Tex implant during the years 1998 to 2002. The current report documents our first case of endolaryngeal extrusion of a Gore-Tex implant.[Abstract] [Full Text] [Related] [New Search]