These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: As, Hg, and Se flue gas sampling in a coal-fired power plant and their fate during coal combustion.
    Author: Otero-Rey JR, López-Vilariño JM, Moreda-Piñeiro J, Alonso-Rodríguez E, Muniategui-Lorenzo S, López-Mahía P, Prada-Rodríguez D.
    Journal: Environ Sci Technol; 2003 Nov 15; 37(22):5262-7. PubMed ID: 14655716.
    Abstract:
    As, Hg, and Se are the most volatile elements in the flue gas from a coal-fired power plant. Significant amounts of these elements cause an undesired direct gaseous emission, which leads to a serious environmental health risk. The main focus of this study is to evaluate the possibility of simultaneous sampling of these volatile elements using an accurate official method for Hg (the most volatile element). A study of As, Hg, and Se emissions from a 1400 MW coal-fired power plant equipped with electrostatic precipitators (ESPs) was carried out for the combustion of a mixture of two types of coal. Simultaneous sampling of coal, bottom ash, fly ash, flue gas, and particles associated with the gas phase has been performed. Flue gas has been sampled by the Ontario Hydro Method Sampling Train, an ASTM method for Hg speciation. This sampling method was tested for As and Se sampling. As and Se determinations have been performed by HG-AAS, and Hg has been determined by CV-AAS. The results were used to examine the following: overall mass balances, relative distribution of these elements in the coal-fired power plant; As, Hg, and Se concentrations in coal and combustion residues; and predominant oxidation state for Hg in flue gas. The mass balances obtained for As, Hg, and Se were satisfactory in all cases; nevertheless, relative enrichment values in fly ash for As and Se were low; therefore, we concluded that As sampling in flue gas can be conducted by application of the Ontario Hydro Method; nevertheless Se released in the gas phase is not completely collected by this sampling train. Application of this sampling method allowed for performance of Hg speciation. The results indicated that Hg(II) was the predominant species in flue gas. It has also been proved that 24%, more than 99.8%, and 90% for As, Hg, and Se in the stack emissions, respectively, were in the gaseous phase.
    [Abstract] [Full Text] [Related] [New Search]