These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator. Author: Hermida JC, Bergula A, Chen P, Colwell CW, D'Lima DD. Journal: J Bone Joint Surg Am; 2003 Dec; 85(12):2325-31. PubMed ID: 14668501. Abstract: BACKGROUND: The use of larger femoral head sizes in total hip arthroplasty has been shown to reduce the rate of dislocation and to increase the range of motion; however, such components have been associated with unacceptably high polyethylene wear rates. Studies have shown dramatic differences in wear rates between nominally cross-linked polyethylene (i.e., polyethylene that is cross-linked during radiation sterilization) and elevated cross-linked polyethylene (i.e., polyethylene that is cross-linked to a higher degree than that obtained by radiation sterilization alone). The aim of this study was to test the effect of increased cross-linking and of increased head size on polyethylene wear rates. METHODS: Four groups of acetabular liners obtained from a single manufacturer, including 28-mm-diameter nominally cross-linked, 32-mm-diameter nominally cross-linked, 28-mm-diameter elevated cross-linked, and 32-mm-diameter elevated cross-linked polyethylene liners, were tested. Three implants from each group were tested in a twelve-station hip wear simulator with use of 90% bovine serum as a lubricant. The liners were articulated with the appropriately sized cobalt-chromium femoral head. Additional liners from each design were subjected only to the same load without motion to serve as load-soak controls to account for any weight gain due to fluid absorption. Gravimetric analysis was performed every 500,000 cycles for a total of five million cycles. RESULTS: Nominally cross-linked liners demonstrated mean wear rates of 14.97 and 16.92 mg per million cycles for the 28-mm and 32-mm head sizes, respectively. Both of the elevated cross-linked liners had significantly lower wear rates than the nominally cross-linked liners, with a mean of 1.51 and 2.57 mg per million cycles for the 28-mm and 32-mm head sizes, respectively (p < 0.001). CONCLUSION: The dramatic reduction in wear rates with polyethylene cross-linking, even with the larger head size, may increase the potential for use of 32-mm head components in total hip arthroplasty.[Abstract] [Full Text] [Related] [New Search]