These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Four-year follow-up of larger-diameter implants placed in fresh extraction sockets using a resorbable membrane or a resorbable alloplastic material.
    Author: Prosper L, Gherlone EF, Redaelli S, Quaranta M.
    Journal: Int J Oral Maxillofac Implants; 2003; 18(6):856-64. PubMed ID: 14696661.
    Abstract:
    PURPOSE: The aim of this randomized study was to evaluate and compare the long-term success rates of cylindric, screw-type titanium implants with a larger diameter (5.9 mm) that were placed in fresh extraction sockets in association with resorbable bone substitutes or a resorbable membrane. MATERIALS AND METHODS: Eighty-three partially edentulous adult patients, selected from among those treated in 1997 and 1998 at the San Raffaele Institute in whom 1 or more implants had been placed into fresh posterior mandibular or maxillary sockets, were included in the study. A total of 111 implants were placed, 36 in mandibles and 75 in maxillae. Fifty-six implants were placed in combination with resorbable hydroxyapatite (HA group) and 55 with a resorbable membrane (MR group). Intraoral radiographs and follow-up examinations, including verification of implant stability via the Periotest, were carried out at second-stage surgery 3, 6, 9, and 12 months later; and then annually up to 4 years after placement of the definitive restoration. The radiographic examination was conducted by means of a standardized procedure to verify osseointegration. RESULTS: There was 100% attendance at the follow-up examination after 4 years. At second-stage surgery, which was performed after 4 to 6 months' healing time, none of the implants showed any signs of mobility, peri-implantitis, or bone loss. Two implants failed in the MR group, one at 3 months and one at 9 months after placement; 1 implant failed in the HA group at 4 months after placement. After 4 years, the implant success rate was 97.3% (108 of 111 implants were considered successful). The success rate did not differ significantly between the HA group (98.2%) and the MR group (96.4%). DISCUSSION: The use of larger-diameter implants served to minimize the anatomic discrepancies that would have evolved when substituting a molar with a standard-diameter implant. According to the accepted criteria for success, the 5-year success rate should be at least 85%; therefore both methods may be considered satisfactory. CONCLUSION: Implants placed in combination with a resorbable allogeneic material or with a resorbable membrane provided predictable long-term results when restored with a fixed partial denture.
    [Abstract] [Full Text] [Related] [New Search]