These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A colour-flicker analysis of visual function in patients with retinal detachment. Author: Fahle M, Troscianko T, Kreissig I. Journal: Ger J Ophthalmol; 1992; 1(5):367-70. PubMed ID: 1477643. Abstract: Patients with a history of retinal detachment were examined by the following tests: (1) setting of an isoluminant match between yellow and green constituent squares of a checkerboard and (2) measurement of the flicker fusion frequency for a contrast-reversal of this yellow-green pattern. The results suggest that the test may provide useful data for assessing the severity of any damage to a given part of the retina. The fusion frequencies range from over 10 Hz (normal) to about 2 Hz for a severely impaired retina. The data for the relative amounts of red and green light needed to achieve a match rarely show any abnormality; thus, a standard anomaloscope test or pseudoisochromatic plates would not detect these deficiencies.[Abstract] [Full Text] [Related] [New Search]