These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Use of studded Polyflex stents in patients with neoplastic obstructions of the central airways.
    Author: Bolliger CT, Breitenbuecher A, Brutsche M, Heitz M, Stanzel F.
    Journal: Respiration; 2004; 71(1):83-7. PubMed ID: 14872116.
    Abstract:
    BACKGROUND: The Polyflex is a commercially available silastic airway stent with proven efficacy. Due to a smooth outer surface its anchorage in the airway wall is superficial which may lead to stent migration. OBJECTIVE: To study the performance of an newer version of the Polyflex stent with a studded outer surface, which should improve anchorage. METHODS: In a 5-centre international study the new stent was prospectively tested in symptomatic patients with neoplastic central airway stenosis of more that 50% of normal diameter. Insertion technique, efficacy of stent placement and stent-related complications were recorded before, 1 month and 3 months post stent placement. RESULTS: Under general anaesthesia and rigid bronchoscopy 27 stents were inserted in 26 patients, mean age: 62 years (range: 37-83), 16 men. Diagnoses were 18 bronchogenic carcinoma, 4 oesophageal carcinoma, 2 metastases, 1 tracheal carcinoma, and 1 schwannoma. The stents were inserted in the following locations: 10 right main bronchus, 8 left main bronchus, 7 trachea, and 2 tracheo-bronchial. There was significant improvement in all functional parameters assessed from before (A), to 1 month (B) and 3 months (C) after stent placement. The measured values (mean +/- SD) were for the WHO scale: A: 2.7 (0.8), B: 1.5 (0.9), C: 1.6 (1.0); for the Karnofsky scale: A: 44 (19), B: 72 (18), C: 71 (21); for the Dyspnoea Index: A: 3.3 (0.7), B: 1.5 (0.8), C: 1.9 (1.2); for FEV(1): A: 1.2 (0.5), B: 1.9 (0.6), C: 1.5 (0.5), and for FVC: A: 2.1 (0.7), B: 2.8 (0.7), C: 2.5 (1.0). Stent-related complications were 4 reversible stent obstructions by secretions, 1 migration. The observation period was mean 4.3 months (range 2 days to 23 months). CONCLUSION: The studded Polyflex showed excellent efficacy, was very well tolerated, and had a very low migration rate. It presents an improvement over the older smooth model and can be considered a true alternative to the most widely used silastic stent, the Dumon stent.
    [Abstract] [Full Text] [Related] [New Search]