These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Osseointegration of a hydroxyapatite-coated multilayered mesh stem.
    Author: Kusakabe H, Sakamaki T, Nihei K, Oyama Y, Yanagimoto S, Ichimiya M, Kimura J, Toyama Y.
    Journal: Biomaterials; 2004 Jul; 25(15):2957-69. PubMed ID: 14967528.
    Abstract:
    A new type of porous coating for hip prostheses called "multilayered mesh" was tested under weight-bearing conditions. The surface of the stem is constructed of titanium mesh produced by etching. The hip stems of hydroxyapatite (HA)-coated multilayered mesh and conventional beads were implanted into canine right hips, and animals were killed 3, 6 and 10 weeks and 6 and 12 months after implantation. Shear strength between the implant and the bone was evaluated by the push-out test. Bone ingrowth was calculated from backscattered electron imaging-scanning electron microscopy (BEI-SEM) images of transverse sections. Toluidine blue stained sections and the BEI-SEM images were evaluated histologically. The break sites of the specimens after the push-out test were evaluated on BEI-SEM images of longitudinal sections. The mean push-out strength of the HA-coated multilayered mesh samples was greater than that of the beads-coated samples every time tested, and the HA-coated multilayered mesh implants had significantly stronger push-out strength at 3 and 6 weeks (p<0.05). The strength of the HA-coated multilayered mesh implants was even greater at 6 and 12 months, whereas the strength of the beads-coated samples decreased. The HA-coated multilayered mesh implants showed significantly higher percentages of bone ingrowth than the beads-coated implants every time tested, except at 6 months (p<0.05). At 6 and 12 months, the bone ingrowth data for the HA-coated multilayered mesh implants increased, whereas it decreased for the beads-coated implants. The new bone formation had reached the bottom of the porous area of the HA-coated multilayered mesh surface by 3 weeks, but not had reached the bottom of the conventional beads surface. At 6 and 12 months, the smaller pores of the bead surface stopped the thickening of trabecular bone, and at 12 months, the break sites were at the bone-implant interface of the bead surface, whereas they were on the bone side of the HA-coated multilayered mesh surface. The difference between the break sites was significant at 12 months (p<0.05). The HA-coated multilayered mesh stem provided faster, stronger, and more durable osseointegration than the conventional bead stem.
    [Abstract] [Full Text] [Related] [New Search]