These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Changes in thrombocytapheresis concentrations caused by leukocyte depletion with polyester filters]. Author: Weisbach V, Riess H, Gindi N, Zeiler T, Riewald M, Zingsem J, Eckstein R. Journal: Infusionsther Transfusionsmed; 1992 Jun; 19(3):146-8. PubMed ID: 1498557. Abstract: We studied platelet loss, leukocyte depletion, T/B-cell-ratio, platelet morphology and platelet function (aggregation, hypotonic shock reaction, retention and retraction) prior to and after filtration through two different polyester filters (Sepacell PL-5A, Pall PL100) as well as the posttransfusional platelet increment 1 h after transfusion in 8 pairs of single donor platelet concentrates (Cobe Spectra, Fresenius AS 104). Leukocyte depletion was effective (greater than 99.9%) and platelet loss acceptable in both filters, all tests showing no indication of a diminished platelet function by filtration.[Abstract] [Full Text] [Related] [New Search]