These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Efficient application of monolithic silica column to determination of illicit heroin street sample by HPLC.
    Author: Macchia M, Bertini S, Mori C, Orlando C, Papi C, Placanica G.
    Journal: Farmaco; 2004 Mar; 59(3):237-9. PubMed ID: 14987987.
    Abstract:
    In this paper, an HPLC method is proposed for a routine, rapid and simple analysis of heroin samples confiscated from the illicit market, based on a new type of packing for HPLC columns (monolithic silica). Acetonitrile and pH 3.5 phosphate buffer solution were used under both isocratic and gradient conditions. Under our analytical conditions, all the components of a typical mixture of an illicit heroin sample proved to be fully separated into well-resolved peaks in 7 min. Analytical linearity and accuracy of the method were also studied for all analytes using tetracaine hydrochloride as the internal standard.
    [Abstract] [Full Text] [Related] [New Search]