These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Venous pressure measurements in the superior and inferior vena cava: the influence of intra-abdominal pressure.
    Author: Markou N, Grigorakos L, Myrianthefs P, Boutzouka E, Rizos M, Evagelopoulou P, Apostolakos H, Baltopoulos G.
    Journal: Hepatogastroenterology; 2004; 51(55):51-5. PubMed ID: 15011830.
    Abstract:
    BACKGROUND/AIMS: To investigate the relationship of pressure in the inferior vena cava (Pivc) with a) pressure in the superior vena cava (Psvc), b) intra-abdominal pressure as measured in the urinary bladder (Pcyst). METHODOLOGY: A prospective study of 38 mechanically ventilated patients. Simultaneous measurements of Psvc, Pivc and Pcyst (151 sets of measurements) were performed. Measurements were divided in: Group A (Pcyst < 10 mmHg), group B (10 mmHg < or = Pcyst < 15 mmHg), group C (Pcyst > or = 15 mmHg). Statistical analysis was performed with paired t-test, Pearson correlation. Results are expressed in mean +/- SEM. RESULTS: In Groups A and B, Psvc and Pivc were not significantly different and they were highly correlated (10.8+/-0.5 mmHg vs. 10.9+/-0.5 mmHg, r=0.93 for Group A and 14.4+/-0.7 mmHg vs. 14.7+/-0.6 mmHg, r=0.87 for Group B). Pcyst was significantly lower than Pivc in both groups. In Group C, Pivc was significantly higher than Psvc (18.9+/-0.7 mmHg vs. 16.4+/-0.7 mmHg). There was no significant difference between Pivc and Pcyst (19.2+/-0.6 mmHg). Pivc significantly correlated with Pcyst (r=0.78) and Psvc (r=0.7). A. When Pcyst > Psvc, Pivc was higher than Psvc (p<0.01). With Pcyst < 15 mmHg, no significant difference was found between Pcyst and Pivc and they were correlated (r=0.766, p<0.05). Pressures in the superior and inferior vena cava were also correlated (r=0.764, p<0.05). With Pcyst > or = 15 mmHg, Pivc was lower than Pcyst (p<0.01). It correlated highly with Pcyst (r=0.85, p<0.01) and less strongly with Psvc (r=0.701, p<0.01). B. When Pcyst < or = Psvc, no difference between Pivc and Psvc was observed. With Pcyst < 15 mmHg, Pivc was higher than Pcyst (p<0.01) and highly correlated with Psvc (r=0.932, p<0.01). Pivc also correlated with Pcyst (r=0.69, p<0.01). With Pcyst > or = 15 mmHg, Pivc was higher than Pcyst (p<0.01) and correlated with Psvc (r=0.74, p<0.01) and Pcyst (r=0.789, p<0.01). CONCLUSIONS: Although Psvc and Pivc are interchangeable in the absence of an increased Pcyst, when Pcyst is high, measurements of Pivc are misleading. A Pcyst > Psvc results in a "waterfall" effect, and Pivc does not accurately reflect Psvc any more.
    [Abstract] [Full Text] [Related] [New Search]